Euro-12 Technical Specification Version 4 Software Total Zones 8 to 12 (end of line) E/S 8 EOL Zones K/P Up to 4. 2 EOL each. Zems EOL 1 Only. 4 EOL. Zems iD 0 Keypads Up to 4} _______} Total not Set Reader Up to 3} to exceed _______} 4 devices. Ward Reader Up to 3} Access Control Up to 3} Codes 12 User Areas 4 Part Sets Wards Up to 3 Shunts 1 Shunt Prog Outputs 1 expandable to 17 with output module Logs 400 Keypad Euro LCD. PIN and PROX Up/down Loading Yes. Euro In-Site via Digi-modem PSU 1.2A or 1.5A SMS Text Yes NVM Type 2465