C-Tec FF388-2 FP 8 Zone panel Expandable to 14 zones

  • Installer-friendly design.
  • Robust metal enclosure c/w lift off lid & heavy-duty base connections.
  • Eight conventional Zone circuits (expandable to 14).
  • Two conventional Sounder circuits.
  • Separate indicators for open & short circuit fault, sounder fault and battery/power supply fault.
  • Non-latching class change sounder output, latching fire & non-latching fault outputs (via expansion loom).
  • Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
  • Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
  • Multi-lingual variants (subject to quantities).
  • Space for 2 x 12V 7Ah VRLA batteries.
  • Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
  • Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).

Technical Specification

Compatibility

Designed to comply with the requirements of BS5839-4 (for head-out monitoring use 1 x BF378M module per zone).

Mains supply

230V 50/60Hz.

Mains rated current

700mA max.

Internal power supply

27V nominal.

Total output current limited to

3A @ 230V.

Quiescent current

70mA (with no mains supply, fault beeper muted, no aux. output connections, EOL devices and resistors only fitted to detector and sounder loops).

Max battery size and type

2 x 12V 7Ah VRLA connected in series.

No. of detector zone circuits

8 (Max. length per circuit is 500m). Up to 6 additional Zones can be added to this panel using FF387Z-2 two zone extender PCB kits. For head out monitoring 1 x BF378M is required per Zone.

Call point resistor value

470 to 680Ω.

Max. devices per detector zone

20 detectors (max. detector current 2mA). No limit for manual call points.

No. of conventional sounder circuits

2 (Max. length per circuit is 500m).

EOL resistor value

6800Ω 5% Tol. 0/25W (blue, grey, red, gold).

Max. sounder output current

3000mA (to all outputs). Outputs are fused at 1A.

Auxiliary relays

1 x onboard relay (1A, 30 VDC, follows sounders). Additional relays available via optional expansion looms (FF374FR, FF374FDR & FF374DT).

Open collector outputs

Available via optional expansion loom FF374X.

Auxiliary inputs

Available via optional expansion loom FF374X..

Indicators

Mains on; Zone Fire; Zone Fault; Sounder Fault; Battery/Power Supply Fault; O/C fault; S/C fault; Zone isolated; Engineer Test selected.

Controls

Reset; Resound; Test Zone Lamps; Evacuate; Silence Alarm Sounders; Silence Fault Sounders; Revert to S/C equals Fire; OMT, Zone Isolate. Keyswitch.

Product dimensions (mm)

521 W x 334 H x D 140mm.

Construction & finish

Metal lid and base.

IP Rating

IP30.

Weight

9.2kg.

Operating conditions/temperature

-5ºC to +40ºC. Max relative humidity: 95%.

Notes

Repeater info: Up to 3 repeaters per main. 5 cores plus 1 per zone. Max. cable length 200m.

  • Model: FF388-2
  • Shipping Weight: 2 kgs
  • Manufactured by: C-Tec
Ask a Question

£479.94 Ex VAT

Add to Cart:

Manufacturer Info

datasheet

Customers who bought this product also purchased...