Firmware
|
V2.x
|
Programmable areas
|
4
|
Max. number of user codes
|
32
|
Event memory
|
1'000 intrusion events, 1'000 access events
|
Number of on-board zones
|
8
|
Max. number of hardwired zones
|
32
|
Max. number of wireless zones
|
32 (take away wired zones)
|
EOL resistor
|
Dual 4k7 (default), other resistor combinations selectable
|
Max. number of outputs
|
30
|
Number of on-board relays
|
1 strobe (30 VDC / 1 A resistive switching current)
|
Number of on-board open coll.
|
2 internal / external bell, 3 freely programmable (each max. 400 mA resistive switching current, supplied via auxiliary output)
|
Door capacity
|
Max. 4 entry doors or 2 entry/exit doors
|
Number of card reader
|
Max. 4
|
Time function
|
4 calendars (53 weeks, multiple on/off switching patterns for users, areas, inputs, outputs, keypads, doors)
|
Macro language
|
Cause & Effect programming (8 triggers / 4 mapping gates)
|
Number of field devices
|
Max. 11 (4 keypads, 2 door-expanders, 5 input/output expanders)
|
Interfaces
|
1 X-BUS (1 spur), 1 RS232, 1 USB (PC connection), 1 SPC Fast Programmer
|
Tamper contact
|
Front spring tamper, 2 auxiliary tamper contact inputs
|
Mains voltage
|
230 VAC, + 10%/ -15%, 50 Hz
|
Operating current
|
Max. 160 mA at 12 VDC
|
Quiescent current
|
Max. 140 mA at 12 VDC
|
Output voltage
|
13-14 VDC in normal conditions (mains powered and fully charged battery)
|
Auxiliary power (nominal)
|
Max. 750 mA at 12 VDC
|
Battery type
|
YUASA NP7-12FR (7 Ah), not supplied
|
Operating temperature
|
0 ~ +40 °C
|
Colour
|
RAL 9003 (signal white)
|
Weight
|
4.500 kg
|
Dimensions (W x H x D)
|
264 x 357 x 81 mm
|
Housing
|
Small metal housing (1.2 mm mild steel)
|