TAKEX 10m Flame & Wide Angle PIR Sensor

A combination UV flame sensor and wide-angle PIR with up to 10m flame and intrusion detection for safer indoor protection of your premises.

  • High sensitivity ultraviolet flame sensor + wide angle intrusion PIR
  • Dual output modes; AND/OR
  • Forced output mode following continued flame detection
  • Alarm memory function
  • Multi-zone PIR technology provides pet immunity up to 20kg (40lbs)
  • PIR area adjustment
  • Detection timer
SPECIFICATIONS  
Detection system

[Flame Sensor]
Ultraviolet rays (Detection wave length 185 to 260nm)

[PIR Sensor]
Passive infrared

Coverage

[Flame Sensor]
33' (10m) with 2.75'' (7cm) lighter flame in front
Approx. 120° conically

[PIR Sensor]
Wide Angle 33' (10m)

Sensitive zone

[PIR Sensor]
Max. 29 pairs

Area adjustment

[PIR Sensor]
3 steps

Supply voltage

10V to 30VDC (non-polarity)

Current consumption

20mA Max.

Alarm output

Individual mode:
Flame sensor output (From ALARM① terminal)
• Dry contact relay (Semi-Conductor) (N.O./N.C. selectable)
• Contact operation : Detection time + off delay. (Approx. 2 sec.)
• Contact capacity : 30V (AC/DC) 0.25A Max. (resistive load)
Passive sensor output (From ALARM② terminal)
• Dry contact relay (Semi-Conductor) (N.O./N.C. selectable)
• Contact operation : One shot (Approx. 2 sec.)
• Contact capacity : 30V (AC/DC) 0.25A Max. (resistive load)

AND mode:
Forced flame signal output (From ALARM① terminal)
When the flame sensor detects a flame twice during the selected AND timer. (Detection time + off delay. Approx. 2 sec.)
Or
When the flame sensor continues to detect a flame for flame duration time 15 or 30 sec. (Detection time after 15/30 sec + off delay. Approx. 2 sec.)
・Dry contact relay (Semi-Conductor) (N.O./N.C. selectable)
・Contact capacity : 30V (AC/DC) 0.25A Max. (resistive load)
AND detection signal output (From ALARM② terminal)
When both passive and flame sensors detect during the selected AND timer. (Detection time, Min. 2 sec.)
・Dry contact relay (Semi-Conductor) (N.O./N.C. selectable)
・Contact capacity : 30V (AC/DC) 0.25A Max. (resistive load)

Alarm memory

Reset after blinking (3 min) and lighting (47 min)
(Operate flame and passive LED individually)

Tamper output

Dry contact relay N.C.
(Activated when the front cover is detached)
Contact capacity: 30V (AC/DC) 0.1A Max. (resistive load)

LED indicator

[Flame Sensor] Red LED:
• Lighting at alarm (Detection time + off delay. Approx. 2 sec.)
• Blinking (3 min) and Lighting (47 min) at memory

[PIR Sensor] Red LED:
• Lighting at alarm (One shot, Approx. 2 sec.)
• Blinking (3 min) and Lighting (47 min) at memory
• Lighting at trouble.

Functions

[Flame Sensor]
Detection timer (1sec, 3sec)

Sensitivity adjustment

[Flame Sensor]
Detection sensitivity (H [100%], L[50%])
*Detection sensitivity can be set only at "Individual" mode.
*H[100%] is fixed at "AND" mode.

Mounting position

Indoor wall surface (Ceiling with optional attachment “BCW-401”)

Wiring

Terminals

Weight

Approx. 120g

Appearance

Resin

  • Model: FP-2500E
  • Shipping Weight: 0.5 kgs
  • Manufactured by: Takex
Ask a Question

£123.21 Ex VAT

Add to Cart:

Manufacturer Info

datasheet