The Scantronic 9751 security system, is a fully programmable panel that can protect up to 24 potentially vulnerable areas of a building.
The system has 8 wired zones and can be expanded up to 24 zones using wired or Class VI wirefree expanders operating on 868 MHz narrow band frequency. This ensures flexibility whatever the installation requirement. Wirefree expanders eliminate the need for complex wiring between devices, causing minimum disruption to the décor.
The 9751 is ideally suited to home security or small commercial security applications and has been designed to provide flexibility and ease of use. It has simple A, B and C settings, providing full and part set options. Up to 4 remote keypads can be added to the system, allowing easy operation from any location using either a 4 digit code or encrypted proximity tag.
To reduce maintenance time, the 9751 has upload/download capabilities allowing the installer to program and perform diagnostic tests remotely. As well as the built in modem for communications, the system has secondary outputs to operate other communication devices.
Specifications
General
|
|
Product name
|
9751
|
Security Grade
|
BS4737
|
Sales number
|
09751UK-50
|
Product Description
|
24 Zone Panel plus 99xx keypad
|
|
|
Capacities
|
|
Max zones
|
24
|
Zones - on board
|
8 FSL or 8CC (with common tamper)
|
Zones - on expander(s)
|
16
|
Standard wired outputs - on board
|
3
|
Communicator outputs:
|
8
|
Outputs on expander module(s)
|
None
|
Setting Levels:
|
1 Full + 2 Part (one partition)
|
Partitions:
|
None
|
Log capacity (events):
|
250
|
No. Keypads
|
4
|
Internal Clock
|
±10 minutes over one year (depending on the accuracy of the mains supply frequency).
|
Downloader
|
Yes
|
Remote Servicing
|
Yes
|
|
|
Security
|
|
Access code
|
4 digits
|
Number of user codes
|
16 plus installer plus duress
|
Code blocking
|
Blocked for 90s after 13 incorrect characters in series.
|
Proximity tag differs
|
4,294,967,296
|
|
|
Physical
|
|
End Station
|
|
End Station dimensions:
|
245(W), 235(H), 90(D) mm
|
End Station weight (w/o battery):
|
2.45 kg
|
Case material
|
Steel
|
|
|
Keypad
|
|
Keypad name
|
9941/9943
|
|
|
Environmental
|
|
Environmental Grade
|
Class II
|
Operating temperature
|
-10° to +55°C
|
Humidity
|
96% RH
|
|
|
Radio
|
|
Expander/Built-in:
|
Expander (see RFX08 or RFX16)
|
|
|
PSTN Communications
|
|
Built in Communicator
|
Yes
|
Plug on communicator
|
No
|
Plug-by communicator
|
Provides 8 programmable outputs for plug-by module.
|
Protocols:
|
Fast Format, SIA, SIA II, SIA III, Contact ID
|
Speech Dialler
|
No
|
ATS rating
|
2
|
Line sharing
|
This product can share a PSTN line with other telephony or fax equipment.
|
REN
|
1
|
|
|
Power Supply
|
|
EN50131-6 Type
|
A
|
Mains power supply
|
230VAC +10%/-15%, 1A max, 50Hz ±5%
|
End station psu
|
13.8VDC, 1.0A
|
End station consumption
|
115mA quiescent, 150mA active
|
Communicator consumption
|
n/a
|
Standby Battery
|
12V rechargeable lead-acid, gel-type battery. Note that a 17Ah battery cannot fit inside the case.
|
Standby time:
|
Depends on battery
|
Max recharge time:
|
Depends on battery
|
12V Aux supply (inc LS)
|
500mA, 12VDC minimum, 13.8VDC maximum, ripple ±2% maximum.
|
14V4 supply
|
None
|
12V Keypad bus
|
None
|
Monitoring includes
|
Mains fail, battery low voltage, battery failure.
|
|
|
Data Connections
|
None
|
|
|
Wired Outputs
|
|
Bell trigger
|
None
|
Strobe trigger
|
None
|
O/P 1
|
Open-collector transistor outputs, 500mA, 12VDC, negative applied.
|
O/P 2
|
Open-collector transistor outputs, 500mA, 12VDC, negative applied.
|
O/P 3
|
Open-collector transistor outputs, 500mA, 12VDC, negative applied.
|
O/P 4
|
None
|
O/P 5-8
|
None
|
LS (loudspeaker)
|
Supports two parallel-connected, externally mounted loudspeakers for internal sounder or EE tones: minimum speaker impedance 16Ω.
|
Communication outputs
|
12V logic outputs, negative applied in alarm (positive removed), 50mA maximum.
|
ST (Siren test)
|
None
|
|
|
Wired Inputs
|
|
TR
|
Tamper return for Bell
|
Tellback/Remote reset**
|
+12V applied to operate reset.
|
Line Fault input**
|
+12V applied to indicate line failure.
|
Aux Tmp
|
None
|
|
|
Fuses
|
|
Mains
|
T-250mA 250V.
|
Other
|
12V Aux = 1A Fast
|
|
Battery = 2A Fast
|